· Fire Alarm Systems
FA-507L Conventional Manual Pull Station
Price on request
View specifications & enquire →Loading your next destination
Loading your next destination
Product information · UAE & GCC
Edwards · Fire Alarm Systems
The EST3 audio amplifiers take full advantage of proven digital technology to deliver highly intelligible voice audio for evacua tion and Mass Notification/Emergency Communication (MNEC) purposes. Digital messages generated by the Audio Source Unit (ASU) and live paging messages are multiplexed into eight separate channels transmitted over fiber optic cable or a single twisted pair of wires. Each zoned amplifier contains integrated de multiplexing circuitry that allows any one of the eight digital audio channels to place messages or signals on the…
Price / availability on request
Request a quotation
Confirm availability, condition, delivery time and final order terms with our team.
The EST3 audio amplifiers take full advantage of proven digital technology to deliver highly intelligible voice audio for evacua tion and Mass Notification/Emergency Communication (MNEC) purposes. Digital messages generated by the Audio Source Unit (ASU) and live paging messages are multiplexed into eight separate channels transmitted over fiber optic cable or a single twisted pair of wires. Each zoned amplifier contains integrated de multiplexing circuitry that allows any one of the eight digital audio channels to place messages or signals on the amplifier’s built-in speaker circuit. Audio channel selection is network software controlled, and audio amplifiers mount in the same enclosures as other EST3 equipment. Power for the amplifiers comes from standard sys tem power supplies through the local rail. Field wiring connects to removable terminal blocks on the amplifier module. Amplifiers support either 25 VRMS or 70 VRMS power limited speaker circuits. For visual signaling, each 20 or 40 watt amplifier comes standard with one 24 Vdc power limited Notification Appliance Circuit.
Three Sizes Available -20 Watts -40 Watts -95 Watts Simultaneous eight channel digital audio – Superior sound quality – Each amplifier does it’s own decoding Speaker circuit built into amplifier – Selectable for 70 or 25 VRMS output – Class A or Class B output – Power limited 3.5 amp 24 Vdc notification appliance circuit on 20 and 40 watt amplifiers – Class A or Class B output – Power limited Network software control of channel selection Integral backup tone generator – 1 KHz temporal (3-3-3) tone evac Part of an end-to-end 520 Hz signaling solution – UL approved for use in sleeping rooms
| 3-ZA20A | 3-ZA40A | 3-ZA95 Agency Listing | UL, ULC, CE, EN54 EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006, and EN 54-16: 2008 | UL, ULC | Environmental | 0°C – 49°C (32°F – 120°F) 93% RH, Non-condensing | | Frequency Response | 400Hz to 4KHz @ +/- 3dB | | Output Voltage | 25 VRMS or 70 VRMS | | THD (distortion | < 7% | | Wire Size | 18 to 12 AWG (1.0 to 2.5 mm²) | | Internal Tone Generator | 1KHz Temporal (3-3-3) Tone (evacuation); 20 PPM (alert) | | SIGA-CC1/2 Support | 10 Units, Maximum | | Standby Current | 62mA for 20 and 40 watt amps; 85mA for the 3-ZA95 watt amp | | Alarm Current | 1120mA | 2480mA | 5540mA Pwr. Ltd. Audio Output Wiring Configuration EOL Resistor | Class A or B 15K Ohms in Class B | Class A or B 15K Ohms in Class B | Class A or B 15K Ohms in Class B Pwr. Ltd. 24 Vdc NAC Wiring Configuration Line Resistance, Max.* EOL Resistor Line Capacitance, Max | Class A or B 50 Ohms, Max. N/A 0.33µF | Class A or B 50 Ohms, Max. N/A 0.33µF | N/A Space Requirements | 1 LRM Space | | 2 LRM Spaces Note: *For EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006, and EN 54-16: 2008 compliant product add suffix -E to model eg. 3-ZA20A-E. Maximum Speaker Circuit Distance at 0.5 dB loss* | | | 70 VRMS Output | 3-ZA20A | 3-ZA40A | 3-ZA95 #12 AWG (3.2 Ohm/1000 ft pair) | 4,536 ft (1,382 m) | 2,268 ft (691 m) | 955 ft (290 m) #14 AWG (5.2 Ohm/1000 ft pair) | 2,792 ft (850 m) | 1,396 ft (425 m) | 588 ft (179 m) #16 AWG (8.0 Ohm/1000 ft pair) | 1,815 ft (553 m) | 907 ft (276 m) | 382 ft (116 m) #18 AWG (13 Ohm/1000 ft pair) | 1,117 ft (340 m) | 558 ft (170 m) | 235 ft (71 m) 25 VRMS Output | 3-ZA20A | 3-ZA40A | 3-ZA95 #12 AWG (3.2 Ohm/1000 ft pair) | 579 ft (176 m) | 289 ft (88 m) | 122 ft (37 m) #14 AWG (5.2 Ohm/1000 ft pair) | 356 ft (108 m) | 178 ft (54 m) | 75 ft (22 m) #16 AWG (8.0 Ohm/1000 ft pair) | 231 ft (70 m) | 116 ft (35 m) | 49 ft (14 m) #18 AWG (13 Ohm/1000 ft pair) | 142 ft (43 m) | 71 ft (21 m) | Not supported by 18 AWG
Request this listed product by its full name and model or manufacturer part number. Safety Shops is based in Ajman Free Zone, UAE. We accept equipment enquiries from the United Arab Emirates, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain.
Include the product link, exact suffix or size, quantity, delivery city and country, and any required project documents. For a replacement, include the installed equipment label so compatibility can be checked. Availability, documentation, shipping feasibility and lead time are confirmed in the quotation. Online Shop checkout delivery is within the UAE; other GCC destinations require an enquiry.