The 3-SSDC1 and 3-SDDC1 Signature Driver Controller modules provide an intelligent interface between the system’s main CPU module and Signature Series devices. Each module contains its own microprocessor used to coordinate, process and interpret information received from and sent to Signature devices. Power and communications is received directly from the control panel rail assembly. The 3-SSDC1 Single Signature Driver Controller module supports one Signature Data circuit, while the 3-SDDC1 Signature Dual Driver Controller module supports two Signature…
Price / availability on request
Request a quotation
Confirm availability, condition, delivery time and final order terms with our team.
The 3-SSDC1 and 3-SDDC1 Signature Driver Controller modules provide an intelligent interface between the system’s main CPU module and Signature Series devices. Each module contains its own microprocessor used to coordinate, process and interpret information received from and sent to Signature devices. Power and communications is received directly from the control panel rail assembly. The 3-SSDC1 Single Signature Driver Controller module supports one Signature Data circuit, while the 3-SDDC1 Signature Dual Driver Controller module supports two Signature circuits. Both modules occupy one rail space in the fire alarm control cabi net and provide removable field wiring terminals to aid installation. Innovative design gives the 3-SSDC1/3-SDDC1 and Signature devices truly “distributed intelligence”. Signature detectors and modules have their own on-board microprocessor communicating with the loop controller in a fully digital communication format. This increases the accuracy of the information coming to and from the loop controller by reducing the effects of capacitance and noise. With decentralized intelligence much of the decision making moves from the loop controller to the devices. Advanced fire detection algorithms processed within the Signature devices effectively end unwanted alarms. Environmental compensation and multiple sens ing element decision making operations are resident in the devices. Intelligent devices allow the Signature Controllers to execute commu nication and system functions with greater speed and low baud rates, increasing the accuracy of information transmitted between the loop controller and devices.
One or two circuit versions Dedicated microprocessor control Full digital communication Specialized communication protocol – Less sensitive to cable characteristics – Utilize existing wiring in most applications Loop alarm in under 750 milliseconds Device location supervision – Unexpected additional device addresses – Missing device addresses – Switched device locations – Programmed device parameters Automatic nonvolatile as-built mapping – Stores “actual” and “expected” device data – Stores physical connection sequence including “T” taps Automatic day/night sensitivity Supports up to 250 intelligent Signature detectors and 250 Intelligent Signature Modules Up to five 3-SDDC1s per node – Total of 10 Signature circuits Removable field wiring terminal blocks Multiple survival modes — stand alone Fully backward compatible with 3-SSDC and 3-SDDC
Catalog Number | 3-SSDC1 | 3-SDDC1 Installation | 1 LRM Space | 1 LRM Space Module Configuration | 1 Addressable circuit (3-SDC1 Card) expandable to 2 circuits. | 2 Addressable circuits (3-SDC1 Cards) Operating Current [Note 2] | Standby 144 mA Alarm 204 mA | Standby 264 mA Alarm 336 mA Operating Voltage | 24 Vdc, Nominal | Address Requirements | Automatic | Detectors Supported | 125 per 3-SDC1 Card | Modules Supported | 125 Module Addresses per 3-SDC1 Card | 2-Wire Smoke Power Output | 100 mA per 3-SDC1 Card (not included in Operating Current above | Conventional detectors supported | 150 of 100 µA type per circuit. | Signature Circuit Voltage | 20 VDC +/- 5% | Maximum Signature Circuit Resistance | 100 Ohms | Maximum Signature Circuit Capacitance | 0.33 µF | Communications Format | 100% Digital | Circuit Wiring Styles | Class B, Class A or Class X | Termination | Removable plug-in terminal strip(s) on module | Permissable Wire Size | 18 to 12 AWG (0.75 to 2.5 mm²) | Agency Listings | UL, ULC (see Note 1); CE, LPCB, EN54 (see Note 3). | Operating Environment | 32 °F (0 °C) to 120 °F (49 °C) 93% RH, non-condensing |
Request this listed product by its full name and model or manufacturer part number. Safety Shops is based in Ajman Free Zone, UAE. We accept equipment enquiries from the United Arab Emirates, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain.
Include the product link, exact suffix or size, quantity, delivery city and country, and any required project documents. For a replacement, include the installed equipment label so compatibility can be checked. Availability, documentation, shipping feasibility and lead time are confirmed in the quotation. Online Shop checkout delivery is within the UAE; other GCC destinations require an enquiry.