· Fire Alarm Systems
FA-507L Conventional Manual Pull Station
Price on request
View specifications & enquire →Loading your next destination
Loading your next destination
Product information · UAE & GCC
Edwards · Fire Alarm Systems
The iO1000 provides one Class A or Class B intelligent device loop that supports up to 250 device addresses. Loop controller modules may be added in combination to expand total system capacity in 250-point increments to up to 1,000 device addresses. The iO1000 panel includes four NACs that may be wired for either Class Auto-programming reduces installation time • Supports Signature Series intelligent modules and detectors • Combines the Signature intelligent releasing module with Signature multisensor detectors for reliable fire suppression • Form C…
Price / availability on request
Request a quotation
Confirm availability, condition, delivery time and final order terms with our team.
The iO1000 provides one Class A or Class B intelligent device loop that supports up to 250 device addresses. Loop controller modules may be added in combination to expand total system capacity in 250-point increments to up to 1,000 device addresses. The iO1000 panel includes four NACs that may be wired for either Class Auto-programming reduces installation time • Supports Signature Series intelligent modules and detectors • Combines the Signature intelligent releasing module with Signature multisensor detectors for reliable fire suppression • Form C contacts for alarm and trouble, Form A for supervisory • Electronic addressing with automatic device mapping • Optional Ethernet port for diagnostics, programming and a variety of system reports • Two programmable switches with LEDs and custom labeling • Supports Genesis horn silence over two wires, and UL 1971-compliant strobe synchronization • Class B or Class A wiring • Ground fault detection by module • Supports up to eight serial annunciators, (LCD, LED-only, and graphic interface) • Can use existing wiring for most retrofit applications • Upload/download remotely or locally • Two-level maintenance alert reporting • Pre-alarm and alarm verification by point • Adjustable detector sensitivity • 4 x 20 character backlit LCD display • Optional earthquake hardening: seismic Importance Factor 1.5 • Standalone operation • Alarm ON command manually activates alarm condition A or Class B operation.
System Capacity: Loops: 1 Class A or Class B intelligent device loop standard, expandable up to 4 loops Device Addresses: Supports up to 250 device addresses per loop, expandable to 1,000 total addresses with additional loop controller modules (iO-SDC1 or iO-SDC2) Notification Appliance Circuits (NACs): 4 Class B NACs standard (configurable to Class A with optional SA-CLA module) Operating Voltage: Input Voltage: 120 VAC @ 60 Hz, 1.3 A max (standard); 230 VAC models available (e.g., iO1000G-2) Loop Voltage: 19 VDC nominal, 15.2–19.95 VDC range Maximum Loop Voltage: 20V peak-to-peak Current Consumption: Standby Current: 125 mA typical (base system, excluding devices) Alarm Current: Up to 3.5 A max (shared across NACs and auxiliary power) Loop Current: 250 µA (standby), 400 µA (activated) per device typical Power Supply: Output: 24 VDC, 3.5 A total (for NACs and auxiliary power) Battery Backup: Supports sealed lead-acid batteries, 7–18 Ah capacity (depending on enclosure and standby needs) Battery Charger: Built-in, supervised, 27.6 VDC charging voltage Notification Appliance Circuits (NACs): Output: 24 VDC, 1.5 A max per NAC (3.5 A total system limit) Synchronization: Supports Genesis horn silence and UL 1971-compliant strobe synchronization Wiring: Class B standard; Class A with optional SA-CLA module Loop Specifications: Wiring: Class B (Style 4) or Class A (Style 6/7 with SA-CLA module) Maximum Loop Length: Up to 10,000 ft (3,048 m) with #18 AWG (0.75 mm²) twisted-pair, unshielded Compatibility: Edwards Signature Series intelligent detectors and modules Environmental Specifications: Operating Temperature: 32°F to 120°F (0°C to 49°C) Storage Temperature: -4°F to 140°F (-20°C to 60°C) Humidity: 0 to 93% RH, non-condensing Display and Interface: Display: 4 x 20 character backlit LCD Indicators: LEDs for Power (green), Alarm (red), Trouble (yellow), Supervisory (yellow), Silence (yellow) Controls: Two programmable switches with LEDs and custom slide-in labels Wiring: Terminals: Screw terminals accepting #18 AWG (0.75 mm²) to #12 AWG (2.5 mm²) Connections: Standard unshielded wiring; ideal for retrofit applications Communication and Connectivity: Addressing: Electronic addressing with automatic device mapping Optional Modules: SA-DACT: Dual-line dialer/modem (supports Contact ID, 4/2 formats) SA-ETH: Ethernet port for diagnostics, programming, and reporting SA-232: RS-232 serial port for printers or computers iO-SDC1: Adds one 250-point loop iO-SDC2: Adds two 250-point loops (500 devices total) RZI16-2: Adds 16 Class B initiating device circuits (IDCs) and 2 Class B NACs Annunciators: Supports up to 8 serial annunciators (LCD, LED, or graphic) Physical Characteristics: Dimensions: Approximately 21.5″ H x 14.5″ W x 4.25″ D (546 mm x 368 mm x 108 mm) Weight: ~20 lbs (9 kg) with enclosure, without batteries Enclosure: Surface-mount, red (e.g., iO1000R) or gray (e.g., iO1000G) door options Certifications: Listings: UL 864, ULC-S527, CSFM, FM Approved Compliance: NFPA 72, ADA accessibility standards Additional Features: Diagnostics: Maintenance alerts, alarm verification by point, adjustable detector sensitivity Programming: Front panel or laptop configuration utility Retrofit Compatibility: Uses existing wiring in most cases, no shielded cable required Relay Outputs: Form C contacts for Alarm and Trouble, Form A for Supervisory Releasing: Supports SIG
Request this listed product by its full name and model or manufacturer part number. Safety Shops is based in Ajman Free Zone, UAE. We accept equipment enquiries from the United Arab Emirates, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain.
Include the product link, exact suffix or size, quantity, delivery city and country, and any required project documents. For a replacement, include the installed equipment label so compatibility can be checked. Availability, documentation, shipping feasibility and lead time are confirmed in the quotation. Online Shop checkout delivery is within the UAE; other GCC destinations require an enquiry.
Price on request