Edwards · Fire Alarm Systems
SIGA-CC1/MCC1 Single Input Signal Modules and SIGA-CC2/ MCC2 Dual Input Signal Modules are part of EDWARDS's Signature Series system. They are intelligent analog addressable devices used for connecting, upon command from the loop controller, supervised Class B signal or telephone circuits to their respective power inputs. The power inputs may be polarized 24 Vdc to operate audible and visible signal appliances or 25 and 70 VRMS to operate audio evacuation speakers and firefighter’s telephones. The actual operation of the SIGA-CC1/MCC1 and SIGA-CC2/…
Price / availability on request
Request a quotation
Confirm availability, condition, delivery time and final order terms with our team.
SIGA-CC1/MCC1 Single Input Signal Modules and SIGA-CC2/ MCC2 Dual Input Signal Modules are part of EDWARDS's Signature Series system. They are intelligent analog addressable devices used for connecting, upon command from the loop controller, supervised Class B signal or telephone circuits to their respective power inputs. The power inputs may be polarized 24 Vdc to operate audible and visible signal appliances or 25 and 70 VRMS to operate audio evacuation speakers and firefighter’s telephones. The actual operation of the SIGA-CC1/MCC1 and SIGA-CC2/ MCC2 is determined by the “personality code” selected by the installer. It is downloaded to the module from the Signature loop controller during system configuration.
Operating voltage range 15.20 to 19.95 VDC Current Standby 310 µA Activated 135 µA Maximum line impedance Refer to the control panel installation manual Ground fault impedance 10 kΩ EOLR 47 kΩ (P/N EOL-47) Circuit designation Signaling line circuits Class A, Style 6 or Class B, Style 4 Telephone riser circuits Class B, Style 4 Notification line circuits Class B, Style Y Wire sizes 12 to 18 AWG (1.0 to 4.0 mm²) Storage temperature range −4 to 140°F (−20 to 60°C)
Operating voltage range 15.20 to 19.95 VDC Current Standby 310 µA Activated 135 µA Maximum line impedance Refer to the control panel installation manual Ground fault impedance 10 kΩ EOLR 47 kΩ (P/N EOL-47) Circuit designation Signaling line circuits Class A, Style 6 or Class B, Style 4 Telephone riser circuits Class B, Style 4 Notification line circuits Class B, Style Y Wire sizes 12 to 18 AWG (1.0 to 4.0 mm²) Storage temperature range −4 to 140°F (−20 to 60°C)
Request this listed product by its full name and model or manufacturer part number. Safety Shops is based in Ajman Free Zone, UAE. We accept equipment enquiries from the United Arab Emirates, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain.
Include the product link, exact suffix or size, quantity, delivery city and country, and any required project documents. For a replacement, include the installed equipment label so compatibility can be checked. Availability, documentation, shipping feasibility and lead time are confirmed in the quotation. Online Shop checkout delivery is within the UAE; other GCC destinations require an enquiry.