3RV2011-1KA10 | Siemens S00 Motor Protection Circuit Breaker 9–12.5A Class 10 DIN Rail

Siemens · Motors & Motion

3RV2011-1KA10 | Siemens S00 Motor Protection Circuit Breaker 9–12.5A Class 10 DIN Rail

Description  The Siemens 3RV2011-1KA10 is a motor protection circuit breaker designed for safeguarding three-phase motors against overloads and short circuits. It provides an adjustable thermal trip range of 9 to 12.5 A with a class 10 protection characteristic and operates at voltages up to 690 VAC. The 3RV2011-1KA10 features a compact S00 frame with screw terminals and DIN rail mounting for control panel integration.     Technical Specifications  Condition New/Never Used Surplus Brand Siemens Category Circuit Breaker Part Number 3RV2011-1KA10 Subcategory Din Rail Mount Circuit Breaker Series / Type 3RV2 Frame Size S00 Voltage Rating 690 VAC Frequency Rating 50/60 Hz Amperage Rating 9–12.5 A Trip Range 9–12.5 FLA Trip Type Thermal Magnetic Motor Protection Class Class 10 Interrupt Rating 6 kA Power Rating 7.5 kW Number of Poles 3 Phase 3 Phase Connection Type Screw terminals Wire Size 18–14 AWG, 12 AWG Mounting Type DIN Rail Enclosure Rating IP20 Operating Temperature −20 to 60 °C Dimensions (H×W×D) 97 × 45 × 96 mm     Information About 3RV2011-1KA10 The 3RV2011-1KA10 is part of the Siemens 3RV2 motor starter protector series developed for reliable motor protection and switching. It is constructed with a thermal-magnetic trip mechanism housed in an S00 frame size suitable for compact installations. The device integrates easily into three-phase motor circuits using standard screw connections and DIN rail mounting. It is commonly used in industrial motor control panels where controlled startup, overload protection, and short-circuit interruption are required. Key Features: Motor protection circuit breaker: Designed specifically for three-phase motor applications. Adjustable thermal trip range: Covers motor currents from 9 to 12.5 A. Class 10 protection: Ensures controlled motor overload response. Thermal-magnetic trip unit: Provides overload and short-circuit protection. Standard switching capacity: Supports typical industrial motor loads. DIN rail mounting: Enables quick installation in control cabinets. Screw terminal connections: Allows secure and straightforward wiring. The 3RV2011-1KA10 delivers the reliability and precision required for industrial motor protection and control panel safety.

Brand: Siemens · Category: Motors & Motion

Key features

Specifications

Manufacturer part number3RV2011-1KA10
ConditionNew/Never Used Surplus
BrandSiemens
CategoryCircuit Breaker
Part Number3RV2011-1KA10
SubcategoryDin Rail Mount Circuit Breaker
Series / Type3RV2
Frame SizeS00
Voltage Rating690 VAC
Frequency Rating50/60 Hz
Amperage Rating9–12.5 A
Trip Range9–12.5 FLA
Trip TypeThermal Magnetic
Motor Protection ClassClass 10
Interrupt Rating6 kA
Power Rating7.5 kW
Number of Poles3
Phase3 Phase
Connection TypeScrew terminals
Wire Size18–14 AWG, 12 AWG
Mounting TypeDIN Rail
Enclosure RatingIP20
Operating Temperature−20 to 60 °C
Dimensions (H×W×D)97 × 45 × 96 mm
Product typeCircuit-Breaker Screw Connection

Contact Safety Shops for pricing, delivery and project support in the UAE.