RA890G1260 | Honeywell Protectorelay Primary Flame Safety Control 120 VAC

Honeywell · Circuit Breakers & Protection

RA890G1260 | Honeywell Protectorelay Primary Flame Safety Control 120 VAC

Description  The Honeywell RA890G1260 is a solid-state Protectorelay primary control used for burner flame safety supervision in industrial and commercial combustion systems. Operating at 120 VAC, it supports ultraviolet flame detection, provides SPDT alarm contacts, and performs a safe-start check with a 15-second safety timing and 3-second flame response for reliable burner protection.     Technical Specifications  Condition New/Never Used Surplus Brand Honeywell Category Flame Safety & Burner Controls Part Number RA890G1260 Subcategory Safety Relay Type Protectorelay primary flame control Voltage 120 VAC Frequency 50/60 Hz Flame Detection Type Ultraviolet (UV) Flame Failure Response Time 3 seconds Safety Timing 15 seconds Alarm Contacts SPDT (Single-Pole Double-Throw) Circuitry Solid-state electronics Recycle Function Recycles if flame is lost during run; locks out if pilot not established Safe-Start Check Prevents startup under flame-simulating fault conditions Ignition Protection Built-in protection against ignition crossover in flame rod systems Operating Temperature -20°F to +115°F (-29°C to +46°C) Mounting Type Base-mounted with captive screws Base Material High-strength thermoplastic Housing Rugged, field-serviceable enclosure Application Burner flame safeguard, primary safety interlock control Compatible Sensors Honeywell UV flame detectors Alarm Output Yes (SPDT relay contacts) Power Consumption Low-power solid-state operation Reset Method Manual reset after lockout Safety Standard Compliance UL listed, CSA certified Typical Use Oil and gas burners, furnaces, and flame safety systems Weight 2.70 lbs (approx. 1.22 kg)   Information About RA890G1260 The RA890G1260 belongs to Honeywell’s reliable RA890 Protectorelay series, designed for primary flame safety control in commercial and industrial burners. This solid-state controller continuously monitors the burner flame through an ultraviolet (UV) flame detection system, recycling operation if the flame signal is lost during the run cycle. If a pilot flame fails to establish within the 15-second safety period, the control initiates a lockout to prevent unsafe operation. Equipped with SPDT alarm contacts and built-in protection against ignition crossover, the RA890G1260 ensures safe burner operation and immediate response to flame failure. The strong thermoplastic base, solid-state design, and self-checking circuitry enhance reliability, while captive mounting screws simplify installation and service. Key Features: Ultraviolet Flame Detection: Works with UV flame sensors for accurate flame monitoring in oil and gas combustion systems. Automatic Recycle Operation: Recycles automatically if flame is lost during operation, ensuring smooth system recovery. Built-In Safety Timing: Features 15-second safety timing and 3-second flame failure response for precise safety supervision. Safe-Start Function: Prevents start-up when flame-simulating faults occur, ensuring operator and system protection. SPDT Alarm Contacts: Provides alarm output for remote fault indication or interlock system integration. Ignition Crossover Protection: Built-in circuitry prevents false flame signals caused by ignition interference. Durable Thermoplastic Base: Strong, heat-resistant housing for long-term stability and easy mounting. Solid-State Reliability: Uses solid-state electronics for reduced wear and enhanced operational life compared to mechanical relays. Service-Friendly Design: Captive mounting screws and plug-in connection simplify installation and maintenance. UL and CSA Certified: Meets international safety standards for flame safeguard systems in industrial environments. The RA890G1260 delivers the reliability and precision required for critical flame safety control in industrial burners, ensuring secure and compliant operation.

Brand: Honeywell · Category: Circuit Breakers & Protection

Key features

Specifications

Manufacturer part numberRA890G1260
ConditionNew/Never Used Surplus
BrandHoneywell
CategoryFlame Safety & Burner Controls
Part NumberRA890G1260
SubcategorySafety Relay
TypeProtectorelay primary flame control
Voltage120 VAC
Frequency50/60 Hz
Flame Detection TypeUltraviolet (UV)
Flame Failure Response Time3 seconds
Safety Timing15 seconds
Alarm ContactsSPDT (Single-Pole Double-Throw)
CircuitrySolid-state electronics
Recycle FunctionRecycles if flame is lost during run; locks out if pilot not established
Safe-Start CheckPrevents startup under flame-simulating fault conditions
Ignition ProtectionBuilt-in protection against ignition crossover in flame rod systems
Operating Temperature-20°F to +115°F (-29°C to +46°C)
Mounting TypeBase-mounted with captive screws
Base MaterialHigh-strength thermoplastic
HousingRugged, field-serviceable enclosure
ApplicationBurner flame safeguard, primary safety interlock control
Compatible SensorsHoneywell UV flame detectors
Alarm OutputYes (SPDT relay contacts)
Power ConsumptionLow-power solid-state operation
Reset MethodManual reset after lockout
Safety Standard ComplianceUL listed, CSA certified
Typical UseOil and gas burners, furnaces, and flame safety systems
Weight2.70 lbs (approx. 1.22 kg)
Product typeSafety Relay

Contact Safety Shops for pricing, delivery and project support in the UAE.