PFC-4064 | Potter Conventional Fire Alarm Control Panel with Ethernet and 5A Power Supply
Potter · Fire & Life Safety
Description The Potter PFC-4064 Conventional Fire Alarm Control Panel is a compact, microprocessor-based unit designed for reliable fire system monitoring and communication. Equipped with six initiating device circuits and four high-current notification appliance circuits, it ensures comprehensive system supervision. With built-in Ethernet connectivity, a 5.0-amp power supply, and support for up to 31 accessories, the PFC-4064 is ideal for both small and expandable fire alarm installations. Technical Specifications Condition New/Never Used Surplus Brand Potter Category Fire Alarm Systems Part Number PFC-4064 Subcategory Conventional Fire Alarm Control Panel Inputs 6 programmable Initiating Device Circuits (expandable to 192) Notification Appliance Circuits (NACs) 4 circuits, 24VDC, 3.0A each Power Supply 5.0A Auxiliary Output 1.0A programmable Display 80-character LCD with status LEDs Communication Built-in Ethernet with listed IP Communicator Connectivity P-Link RS-485 bus supports up to 31 accessories Compliance UL-864, NFPA-70, NFPA-72 Cabinet Metal enclosure with key lock and Lexan viewing window Battery Capacity Supports up to two 12VDC, 18AH batteries Synchronization Strobe sync for Gentex®, Amseco®, System Sensor®, Cooper/Wheelock® Programming Onboard keypad navigation and limited configuration Event History Buffer Built-in for recorded events Dimensions 14 × 4 × 18 in Weight 15 lbs Information About PFC-4064 The PFC-4064 is a UL-864, NFPA-70, and NFPA-72 compliant conventional fire alarm control panel from Potter Electric Signal Company. It features a modular design that supports expansion up to 192 input circuits using IDC-6 modules, allowing adaptability for various building sizes and applications. Its metal enclosure includes a key lock and Lexan viewing window for secure system access, while the backlit LCD and LED indicators provide clear system visibility. Designed for both performance and convenience, the PFC-4064 integrates strobe synchronization, Ethernet connectivity, and a P-Link RS-485 bus for seamless integration with Potter system accessories. Key Features: Six Programmable IDCs: Provides flexible configuration options for fire detection zones. Expandable Design: Supports up to 192 input circuits using IDC-6 expansion modules. Powerful Supply: 5.0A power supply with four NACs rated at 3.0A each for reliable signaling. Strobe Synchronization: Compatible with Gentex®, Amseco®, System Sensor®, and Cooper/Wheelock® devices. Integrated Ethernet: Built-in IP communicator allows remote monitoring and e-mail notifications. Auxiliary Output: 1.0A programmable output for additional fire alarm control functions. User-Friendly Interface: 80-character LCD display and system LEDs for clear status visibility. Accessory Support: P-Link RS-485 bus supports up to 31 system accessories for enhanced scalability. The PFC-4064 delivers the reliability and precision required for professional-grade fire detection, notification, and system supervision applications.
Brand: Potter · Category: Fire & Life Safety
Key features
- Six Programmable IDCs: Provides flexible configuration options for fire detection zones.
- Expandable Design: Supports up to 192 input circuits using IDC-6 expansion modules.
- Powerful Supply: 5.0A power supply with four NACs rated at 3.0A each for reliable signaling.
- Strobe Synchronization: Compatible with Gentex®, Amseco®, System Sensor®, and Cooper/Wheelock® devices.
- Integrated Ethernet: Built-in IP communicator allows remote monitoring and e-mail notifications.
- Auxiliary Output: 1.0A programmable output for additional fire alarm control functions.
- User-Friendly Interface: 80-character LCD display and system LEDs for clear status visibility.
- Accessory Support: P-Link RS-485 bus supports up to 31 system accessories for enhanced scalability.
Specifications
| Manufacturer part number | PFC-4064 |
|---|---|
| Condition | New/Never Used Surplus |
| Brand | Potter |
| Category | Fire Alarm Systems |
| Part Number | PFC-4064 |
| Subcategory | Conventional Fire Alarm Control Panel |
| Inputs | 6 programmable Initiating Device Circuits (expandable to 192) |
| Notification Appliance Circuits (NACs) | 4 circuits, 24VDC, 3.0A each |
| Power Supply | 5.0A |
| Auxiliary Output | 1.0A programmable |
| Display | 80-character LCD with status LEDs |
| Communication | Built-in Ethernet with listed IP Communicator |
| Connectivity | P-Link RS-485 bus supports up to 31 accessories |
| Compliance | UL-864, NFPA-70, NFPA-72 |
| Cabinet | Metal enclosure with key lock and Lexan viewing window |
| Battery Capacity | Supports up to two 12VDC, 18AH batteries |
| Synchronization | Strobe sync for Gentex®, Amseco®, System Sensor®, Cooper/Wheelock® |
| Programming | Onboard keypad navigation and limited configuration |
| Event History Buffer | Built-in for recorded events |
| Dimensions | 14 × 4 × 18 in |
| Weight | 15 lbs |
| Product type | Conventional Fire Alarm Control Panel |
Contact Safety Shops for pricing, delivery and project support in the UAE.