Description  The Notifier NZM-100-6 is a six-input zone module that allows integration of conventional two-wire detectors with intelligent fire alarm systems. Designed for flexibility, it supports either six Class B or three Class A circuits, providing seamless communication between conventional detection zones and addressable systems. This compact module ensures reliable supervision, monitoring, and reporting of zone conditions in fire protection networks.     Technical Specifications  Condition New/Never Used Surplus Brand Notifier Category Fire Safety Part Number NZM-100-6 Subcategory Zone Module Dimensions 6.80 × 5.80 × 1.25 in Weight 1.10 lbs Inputs Six Class B or three Class A circuits Standby Current 2.0 mA Alarm Current 40 mA Operating Voltage From SLC, system dependent Wire Range 12–18 AWG Indicators Panel-controlled bi-color LEDs Addressing Rotary switches, 01–159 Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10% to 93% non-condensing Mounting Options BB-XP, CHS-6 in CAB-3, CAB-4, BB-25 Approvals UL, ULC, FM, CSFM, MEA     Information About NZM-100-6 The NZM-100-6 is part of the Notifier FireWarden series of interface modules. It enables fire alarm control panels to connect to conventional two-wire detector circuits while maintaining full supervision and system integrity. Each module uses a common SLC input and supports removable terminal blocks for simplified wiring. Rotary switches provide straightforward addressing, while panel-controlled LED indicators give clear status visibility. With mounting options for multiple cabinets and chassis, the NZM-100-6 adapts to a wide range of installation environments. Key Features: Multiple Circuit Options: Supports six Class B or three Class A initiating device circuits. Easy Addressing: Rotary address switches simplify configuration and reduce programming errors. Removable Terminal Blocks: Accepts 12–18 AWG wiring for straightforward installation. Status Indicators: Panel-controlled LEDs display point conditions for clear diagnostics. Flexible Mounting: Compatible with BB-XP, CHS-6, CAB-3, CAB-4, and BB-25 enclosures. Independent Operation: Each circuit functions independently despite sharing common supply and ground. Disable Unused Addresses: Allows freeing up of unused points for system efficiency. Agency Approvals: UL, ULC, CSFM, MEA, and FM certified for compliance. The NZM-100-6 delivers the reliability and precision required for professional fire detection system integration.

Brand: Notifier · Category: Sensors & Instrumentation

Key features

Specifications

Manufacturer part numberNZM-100-6
ConditionNew/Never Used Surplus
BrandNotifier
CategoryFire Safety
Part NumberNZM-100-6
SubcategoryZone Module
Dimensions6.80 × 5.80 × 1.25 in
Weight1.10 lbs
InputsSix Class B or three Class A circuits
Standby Current2.0 mA
Alarm Current40 mA
Operating VoltageFrom SLC, system dependent
Wire Range12–18 AWG
IndicatorsPanel-controlled bi-color LEDs
AddressingRotary switches, 01–159
Operating Temperature32°F to 120°F (0°C to 49°C)
Humidity Range10% to 93% non-condensing
Mounting OptionsBB-XP, CHS-6 in CAB-3, CAB-4, BB-25
ApprovalsUL, ULC, FM, CSFM, MEA
Product typeZone Module