NCA-2 | Notifier Network Control Annunciator 640-Character Display
Notifier · HMIs & Displays
Description The Notifier NCA-2 Network Control Annunciator is a second-generation control and display module for NOTI•FIRE•NET networks. It provides 640-character LCD annunciation and full network-wide system control for ONYX® Series fire alarm panels, enabling centralized monitoring, command, and event management. Technical Specifications Condition New/Never Used Surplus Brand Notifier Category Fire Alarm Components Part Number NCA-2 Subcategory Network Control Annunciator Display Type 640-Character Backlit LCD Key Interface QWERTY Keypad, Soft Keys, and Fixed Function Keys Compatibility NFS2-3030, NFS-3030, NFS-320, NFS-640, NFS2-640, and DVC Series Network Type NOTI•FIRE•NET History Buffer 1000 Alarm Events, 4000 System Events Control Functions Acknowledge, Silence, Reset, Enable/Disable, Lamp Test Programming Online Programming and Alter-Status Functions Reports Printable Programming and History Reports Event Display Filtered Reports by Alarm, Trouble, Supervisory, Security, or Time Range User Access One Master and Nine User Password Levels Additional Functions Walk-Test Program, Timer Controls, HVAC/Smoke Control Compliance NFPA FSCS, Canadian ULC Display Requirements Mounting Control Cabinet or Wall-Mount Enclosure Power Requirements Supplied via Network Node or External Power Supply Weight 2.00 lbs Information About NCA-2 The NCA-2 is a comprehensive network annunciator and control interface for NOTIFIER’s NOTI•FIRE•NET systems, designed for centralized system operation and monitoring. It features a 640-character backlit LCD with an intuitive QWERTY keypad, programmable soft keys, and dedicated hard keys for critical control functions. Compatible with ONYX® Series panels such as the NFS2-3030 and NFS-640, it can serve as either a network-wide control point or the primary display for displayless nodes. The NCA-2 allows operators to perform event acknowledgment, silence, reset, and enable/disable functions, while providing detailed event history, alarm tracking, and report generation. Its programmable user access levels and compliance with NFPA and ULC requirements make it a robust and secure solution for large-scale fire alarm networks. Key Features: High-Resolution Display: 640-character backlit LCD provides clear, comprehensive system information and event details. Full Network Control: Enables global command of alarms, silencing, resets, and system enable/disable across all ONYX Series nodes. Advanced Event Management: Stores 1000 alarm and 4000 system events, filterable by type or time for efficient review. Integrated QWERTY Interface: Offers intuitive programming and operation with interactive soft and hard key navigation. Programmable Access Control: Includes 10 user levels with password protection and customizable permissions. Comprehensive Reporting: Supports real-time history and configuration printing for system documentation. HVAC and Smoke Control Support: Meets NFPA Firefighter Smoke Control Station (FSCS) requirements. ULC and NFPA Compliant: Certified for use in fire detection and life-safety network applications. The NCA-2 delivers the reliability and precision required for centralized control, monitoring, and event management across Notifier’s networked fire alarm systems.
Brand: Notifier · Category: HMIs & Displays
Key features
- High-Resolution Display: 640-character backlit LCD provides clear, comprehensive system information and event details.
- Full Network Control: Enables global command of alarms, silencing, resets, and system enable/disable across all ONYX Series nodes.
- Advanced Event Management: Stores 1000 alarm and 4000 system events, filterable by type or time for efficient review.
- Integrated QWERTY Interface: Offers intuitive programming and operation with interactive soft and hard key navigation.
- Programmable Access Control: Includes 10 user levels with password protection and customizable permissions.
- Comprehensive Reporting: Supports real-time history and configuration printing for system documentation.
- HVAC and Smoke Control Support: Meets NFPA Firefighter Smoke Control Station (FSCS) requirements.
- ULC and NFPA Compliant: Certified for use in fire detection and life-safety network applications.
Specifications
| Manufacturer part number | NCA-2 |
|---|---|
| Condition | New/Never Used Surplus |
| Brand | Notifier |
| Category | Fire Alarm Components |
| Part Number | NCA-2 |
| Subcategory | Network Control Annunciator |
| Display Type | 640-Character Backlit LCD |
| Key Interface | QWERTY Keypad, Soft Keys, and Fixed Function Keys |
| Compatibility | NFS2-3030, NFS-3030, NFS-320, NFS-640, NFS2-640, and DVC Series |
| Network Type | NOTI•FIRE•NET |
| History Buffer | 1000 Alarm Events, 4000 System Events |
| Control Functions | Acknowledge, Silence, Reset, Enable/Disable, Lamp Test |
| Programming | Online Programming and Alter-Status Functions |
| Reports | Printable Programming and History Reports |
| Event Display | Filtered Reports by Alarm, Trouble, Supervisory, Security, or Time Range |
| User Access | One Master and Nine User Password Levels |
| Additional Functions | Walk-Test Program, Timer Controls, HVAC/Smoke Control |
| Compliance | NFPA FSCS, Canadian ULC Display Requirements |
| Mounting | Control Cabinet or Wall-Mount Enclosure |
| Power Requirements | Supplied via Network Node or External Power Supply |
| Weight | 2.00 lbs |
| Product type | Network Control Annunciator |