FD-H22F | Keyence Clamp-On Hose Flow Sensor, 13–22.9 mm, 0 60 L/min, IO-Link

Keyence · Sensors & Instrumentation

FD-H22F | Keyence Clamp-On Hose Flow Sensor, 13–22.9 mm, 0 60 L/min, IO-Link

Description  The Keyence FD-H22F is a clamp-on flow sensor hose model designed for precise, non-intrusive measurement of liquids through soft plastic or rubber piping. It supports a pipe diameter range of Ø13–22.9 mm (0.51"–0.90") and measures flow rates up to 60 L/min (15.9 gal/min) using advanced Delta TOF ultrasonic detection technology.     Technical Specifications  Condition New/Never Used Surplus Brand Keyence Category Sensors & Switches Part Number FD-H22F Subcategory Flow Sensor Type Hose model Supported Pipe Diameter Ø13–22.9 mm (0.51"–0.90") Supported Pipe Materials Soft plastic, braided hoses, rubber hoses Supported Fluids All fluids (water, oil, chemicals) Fluid Temperature 0–100°C (32–212°F) Maximum Rated Flow 60 L/min (15.9 gal/min) Zero Cut Flow Rate 0.5 L/min (0.13 gal/min) Detection Principle Delta TOF (ultrasonic time-of-flight) Display QVGA 2.0 color LCD with status indicator Display Update Rate Approx. 10 times/second Display Resolution 0.01/0.1/1.0 L/min (default: 0.1) Response Time 0.5 / 1 / 2.5 / 5 / 10 / 30 / 60 / 120 / 200 s selectable Measurement Accuracy ±1.0% (typical) Repeatability ±0.5% of F.S. or better Flow Units L/min, m³/h, G/min IO-Link Support Ver.1.1 compatible Analog Output 4–20 mA / 0–20 mA, 500 Ω or less Power Supply 24 VDC nominal (18–30 VDC) Current Consumption 240 mA or less Enclosure Rating IP65 / IP67 Ambient Temperature Sensor head: -20 to +60°C (-4 to +140°F) Relative Humidity 35–85% RH (non-condensing) Vibration Resistance 10–500 Hz, 10 sweeps each in X, Y, and Z axes Shock Resistance 100 m/s² (16 ms pulses, 1000 times each axis) Materials Body: PPS/PET/PAR; Bracket: SUS304; Cable: PVC Data Interface USB 2.0 Weight Approx. 770 g (1.7 lbs)     Information About FD-H22F The FD-H22F belongs to the Keyence FD-H Series of clamp-on ultrasonic flow sensors, engineered for accurate and maintenance-free monitoring of various fluids including water, oil, and chemicals. Using a time-of-flight (Delta TOF) measurement system, it ensures stable flow readings without fluid contamination or pressure loss. The unit features a QVGA color LCD display, IO-Link communication, and multiple analog or pulse output options for easy system integration. Its IP65/IP67-rated construction and wide operating temperature range make it ideal for industrial, laboratory, and process control environments. Key Features: Non-Intrusive Measurement: Clamp-on design eliminates the need to cut or modify piping. Wide Pipe Compatibility: Supports hose diameters from Ø13–22.9 mm (0.51"–0.90") across various flexible materials. High Flow Capacity: Accurately measures up to 60 L/min (15.9 gal/min) for water, oil, and chemical applications. Advanced Delta TOF Detection: Ensures fast, accurate, and stable flow detection without fluid contact. Wide Fluid Temperature Range: Handles 0 to 100°C (32 to 212°F) with no freezing on pipe surfaces. Multi-Function Display: High-resolution QVGA color LCD with integrated status indicator light for easy monitoring. Flexible Output Options: Includes NPN/PNP, analog (4–20 mA / 0–20 mA), and pulse output modes. IO-Link Communication: Enables advanced data exchange and integration with modern automation systems. Rugged Environmental Resistance: Rated IP65/IP67 and resistant to vibration, shock, and harsh industrial conditions. Built-in Heat Calculation: Provides energy monitoring in MJ/h, kW, or kBTU/h for process optimization. The FD-H22F delivers the precision, convenience, and reliability required for flow measurement in chemical processing, cooling, and fluid distribution systems.

Brand: Keyence · Category: Sensors & Instrumentation

Key features

Specifications

Manufacturer part numberFD-H22F
ConditionNew/Never Used Surplus
BrandKeyence
CategorySensors & Switches
Part NumberFD-H22F
SubcategoryFlow Sensor
TypeHose model
Supported Pipe DiameterØ13–22.9 mm (0.51"–0.90")
Supported Pipe MaterialsSoft plastic, braided hoses, rubber hoses
Supported FluidsAll fluids (water, oil, chemicals)
Fluid Temperature0–100°C (32–212°F)
Maximum Rated Flow60 L/min (15.9 gal/min)
Zero Cut Flow Rate0.5 L/min (0.13 gal/min)
Detection PrincipleDelta TOF (ultrasonic time-of-flight)
DisplayQVGA 2.0 color LCD with status indicator
Display Update RateApprox. 10 times/second
Display Resolution0.01/0.1/1.0 L/min (default: 0.1)
Response Time0.5 / 1 / 2.5 / 5 / 10 / 30 / 60 / 120 / 200 s selectable
Measurement Accuracy±1.0% (typical)
Repeatability±0.5% of F.S. or better
Flow UnitsL/min, m³/h, G/min
IO-Link SupportVer.1.1 compatible
Analog Output4–20 mA / 0–20 mA, 500 Ω or less
Power Supply24 VDC nominal (18–30 VDC)
Current Consumption240 mA or less
Enclosure RatingIP65 / IP67
Ambient TemperatureSensor head: -20 to +60°C (-4 to +140°F)
Relative Humidity35–85% RH (non-condensing)
Vibration Resistance10–500 Hz, 10 sweeps each in X, Y, and Z axes
Shock Resistance100 m/s² (16 ms pulses, 1000 times each axis)

Contact Safety Shops for pricing, delivery and project support in the UAE.