HPF602ULADA | Honeywell 6.0 A Fire Alarm Notification Power Supply, 24VDC, UL Listed
Honeywell · Fire & Life Safety
Description The Honeywell HPF602ULADA Fire Alarm Power Supply is a 6.0 A notification power expander designed to extend and support fire alarm and security systems with reliable, regulated power. It features a built-in AC power connection, battery charging circuit, and backup battery space, making it an ideal choice for powering notification appliances required under ADA compliance. With advanced switch-mode design, ANSI cadence pattern output, and built-in synchronization for System Sensor, Gentex, Wheelock, and Faraday appliances, the HPF602ULADA offers superior value and performance. Its lightweight design simplifies installation while providing full supervision and dependable operation in critical applications. Technical Specifications Condition New/Never Used Surplus Brand Honeywell Power Products Category Fire Alarm Accessories Part Number HPF602ULADA UPC 783196011387 Also Known As 0H-F602ULADA AC Input 120 VAC at 2.0 A Output Power 24 VDC @ 6.0 A (total across all outputs) Output Per Circuit 3.0 A Output Configurations 2 Class A, 4 Class B, or 1 Class A + 2 Class B Auxiliary Outputs 4 continuous Inputs 2 (configurable as 2 Class A or 2 Class B) Input Voltage Range 9–32 VDC Battery Capacity Supports up to 33 AH Current Draw (Battery) 75 mA standby, 175 mA alarm Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity 85% non-condensing max Dimensions 16.0" H × 12.25" W × 3.0" D (40.64 × 30.88 × 7.62 cm) Indicators AC Power (green), Battery Trouble (yellow), Ground Fault (yellow), Output Troubles (yellow) Compliance Standards UL 864, UL 1481, NFPA 72, CSFM Approved Listings UL Listed (File S6677), CSFM: 7300-1637 Information About HPF602ULADA The Honeywell HPF602ULADA expands fire alarm system capacity by delivering up to 6.0 A of filtered 24 VDC power to support horns, strobes, and other notification appliances. It allows connection to Class A or Class B type circuits and ensures instantaneous switchover to standby battery power in the event of AC failure. Built-in diagnostics and LED indicators simplify troubleshooting, while UL 864, UL 1481, NFPA 72, and CSFM compliance ensure reliable and code-approved system performance. Whether powering additional devices, syncing strobes across large systems, or upgrading legacy panels with cadence capability, the HPF602ULADA provides a robust and cost-effective solution. Key Features: Provides 6.0 A of notification appliance power. 24 VDC filtered output with switch-mode design. Four power-limited outputs: configurable as 2 Class A, 4 Class B, or 1 Class A + 2 Class B. Additional continuous auxiliary output. Built-in synchronization for System Sensor, Gentex, Wheelock, and Faraday appliances. ANSI cadence pattern output for upgrading older panels. Instant battery switchover during AC failure. LED indicators for quick diagnosis of power, ground fault, and trouble conditions. Lightweight design reduces installation time and shipping cost. Fully compliant with UL 864, UL 1481, and NFPA 72 fire safety standards.
Brand: Honeywell · Category: Fire & Life Safety
Key features
- Provides 6.0 A of notification appliance power.
- 24 VDC filtered output with switch-mode design.
- Four power-limited outputs: configurable as 2 Class A, 4 Class B, or 1 Class A + 2 Class B.
- Additional continuous auxiliary output.
- Built-in synchronization for System Sensor, Gentex, Wheelock, and Faraday appliances.
- ANSI cadence pattern output for upgrading older panels.
- Instant battery switchover during AC failure.
- LED indicators for quick diagnosis of power, ground fault, and trouble conditions.
- Lightweight design reduces installation time and shipping cost.
- Fully compliant with UL 864, UL 1481, and NFPA 72 fire safety standards.
Specifications
| Manufacturer part number | HPF602ULADA |
|---|---|
| Condition | New/Never Used Surplus |
| Brand | Honeywell Power Products |
| Category | Fire Alarm Accessories |
| Part Number | HPF602ULADA |
| UPC | 783196011387 |
| Also Known As | 0H-F602ULADA |
| AC Input | 120 VAC at 2.0 A |
| Output Power | 24 VDC @ 6.0 A (total across all outputs) |
| Output Per Circuit | 3.0 A |
| Output Configurations | 2 Class A, 4 Class B, or 1 Class A + 2 Class B |
| Auxiliary Outputs | 4 continuous |
| Inputs | 2 (configurable as 2 Class A or 2 Class B) |
| Input Voltage Range | 9–32 VDC |
| Battery Capacity | Supports up to 33 AH |
| Current Draw (Battery) | 75 mA standby, 175 mA alarm |
| Operating Temperature | 32°F to 120°F (0°C to 49°C) |
| Humidity | 85% non-condensing max |
| Dimensions | 16.0" H × 12.25" W × 3.0" D (40.64 × 30.88 × 7.62 cm) |
| Indicators | AC Power (green), Battery Trouble (yellow), Ground Fault (yellow), Output Troubles (yellow) |
| Compliance Standards | UL 864, UL 1481, NFPA 72, CSFM Approved |
| Listings | UL Listed (File S6677), CSFM: 7300-1637 |
| Product type | Fire Alarm Power Supplies |