RM7895A1030 | Honeywell Fulton RM7800 Primary Burner Control

Honeywell · HVAC & Building Controls

RM7895A1030 | Honeywell Fulton RM7800 Primary Burner Control

Description  The Honeywell Fulton RM7895A1030 is an on-off primary burner control designed for safe and reliable burner sequencing within RM7800 flame safeguard systems. It operates on 120 VAC and supports intermittent pilot operation with integrated airflow safety checks and prepurge capability.     Technical Specifications  Condition New/Never Used Surplus Brand Honeywell Category Flame Safeguard & Burner Controls Part Number RM7895A1030 Subcategory Primary Burner Controls Product Series RM7800 (Fulton Edition) Control Type On-Off Primary Burner Control Supply Voltage 120 VAC (+10%, -15%) Frequency 50/60 Hz (±10%) Pilot Type Intermittent Pilot Flame Establishing Period 4 or 10 Seconds (Limited) Main Flame Establishing Period Intermittent Prepurge Control ST7800A Purge Timer Card Airflow Switch Check Included Interlocks Selectable Compatible Flame Amplifiers R7847, R7848, R7849, R7851, R7852, R7861, R7886 Required Subbase Q7800A or Q7800B Vibration Tolerance 5 G Environment Storage Temperature -40 to +140 °F (-40 to +60 °C) Weight 1 lb 15 oz (0.9 kg)   Information About RM7895A1030 The RM7895A1030 is part of the Honeywell RM7800 Series, specifically configured for Fulton burner applications requiring dependable on-off combustion control. It coordinates burner startup, flame supervision, and shutdown while supporting configurable safety interlocks and airflow verification. The module operates with interchangeable flame amplifiers and external purge timing cards to allow system flexibility. Nonvolatile memory preserves operating history and sequencing data to assist with diagnostics and maintenance. Key Features Automatic Burner Sequencing: Controls safe startup, operation, and shutdown of on-off burner systems. Prepurge Capability: Supports controlled prepurge timing through the ST7800A purge timer card. Intermittent Pilot Support: Manages pilot and main flame establishing periods for compliant burner operation. Dynamic Airflow Verification: Includes airflow switch checking to confirm safe combustion conditions. Modular Flame Detection: Accepts multiple interchangeable flame amplifiers for application flexibility. Integrated Diagnostics: Five LED indicators provide real-time status, sequence, and fault information. Nonvolatile Memory Storage: Retains history and sequencing data after power interruptions. The RM7895A1030 delivers the reliability and precision required for safe primary burner control in commercial and industrial combustion systems.

Brand: Honeywell · Category: HVAC & Building Controls

Key features

Specifications

Manufacturer part numberRM7895A1030
ConditionNew/Never Used Surplus
BrandHoneywell
CategoryFlame Safeguard & Burner Controls
Part NumberRM7895A1030
SubcategoryPrimary Burner Controls
Product SeriesRM7800 (Fulton Edition)
Control TypeOn-Off Primary Burner Control
Supply Voltage120 VAC (+10%, -15%)
Frequency50/60 Hz (±10%)
Pilot TypeIntermittent
Pilot Flame Establishing Period4 or 10 Seconds (Limited)
Main Flame Establishing PeriodIntermittent
Prepurge ControlST7800A Purge Timer Card
Airflow Switch CheckIncluded
InterlocksSelectable
Compatible Flame AmplifiersR7847, R7848, R7849, R7851, R7852, R7861, R7886
Required SubbaseQ7800A or Q7800B
Vibration Tolerance5 G Environment
Storage Temperature-40 to +140 °F (-40 to +60 °C)
Weight1 lb 15 oz (0.9 kg)
Product typePrimary Burner Controls

Contact Safety Shops for pricing, delivery and project support in the UAE.