Description  The R8182H1070 is a combination Protectorelay and hydronic heating controller designed for reliable burner and circulator management in intermittent ignition systems. It integrates high and low limit controls, circulator control, and safety lockout functionality in a compact junction box-mounted form.     Technical Specifications  Condition New/Never Used Surplus Brand Honeywell Category HVAC Part Number R8182H1070 Subcategory Burner Control Voltage 120 VAC Frequency 60 Hz High Limit Range 130°F to 240°F Low Limit Range 110°F to 220°F Differential Range High: 10°F fixed; Low: 10°F–25°F adjustable Timing Safety Switch 45 seconds Ignition Load (VA) 360 VA Burner AFL Rating 4.4 A at 120 VAC Power Consumption 9 W Operating Humidity 0% to 95% RH (non-condensing) Max Ambient Temp 250°F at element Max Pressure 200 psi (well), 100 psi (direct immersion) Dimensions (H × W × D) 7-1/8″ × 5-1/4″ × 3-7/16″ Weight 6.00 lbs       Information About R8182H1070 The R8182H1070 is a versatile aquastat control module used in residential and light commercial hydronic heating systems. The controller offers a high limit range of 130°F to 240°F and a low limit range of 110°F to 220°F, with a differential adjustment of 10°F to 25°F on the circulator circuit. It features a 45-second safety switch lockout, burner AFL rating of 4.4 A at 120 VAC, and supports zone control via ZC and ZR terminals. Mounted on a 4 × 4 in. junction box, it includes a 5 ft armored capillary sensor and supports manual reset after safety shutdowns. Compatible with cadmium sulfide flame detectors and 24 VAC thermostats, the R8182H1070 ensures safe, efficient temperature regulation and control. Key Features: Dual Temperature Range: High limit range: 130°F to 240°F; Low limit range: 110°F to 220°F. Adjustable Differential: 10°F fixed (high limit); 10°F to 25°F adjustable (low limit/circulator). Safety Lockout Feature: 45-second safety switch timing with manual reset required after flame failure. Mounting Configuration: Junction box mounting with 5 ft armored capillary and remote sensor. Ignition Compatibility: Designed for intermittent ignition applications with flame safeguard. Electrical Ratings: Burner AFL: 4.4 A @ 120 VAC; Ignition load: 360 VA; Max power consumption: 9 W. Zone Control Support: Compatible with ZC and ZR terminals for zone valve control. Environment Tolerance: Operates in 0–95% RH (non-condensing) and up to 250°F ambient. Dimensions: 7-1/8″ height × 5-1/4″ width × 3-7/16″ depth. Max Operating Pressure: 200 psi (immersion well) or 100 psi (direct immersion). The R8182H1070 offers precise hydronic control and integrated safety features ideal for advanced residential heating systems.

Brand: Honeywell · Category: Fire & Life Safety

Key features

Specifications

Manufacturer part numberR8182H1070
ConditionNew/Never Used Surplus
BrandHoneywell
CategoryHVAC
Part NumberR8182H1070
SubcategoryBurner Control
Voltage120 VAC
Frequency60 Hz
High Limit Range130°F to 240°F
Low Limit Range110°F to 220°F
Differential RangeHigh: 10°F fixed; Low: 10°F–25°F adjustable
Timing Safety Switch45 seconds
Ignition Load (VA)360 VA
Burner AFL Rating4.4 A at 120 VAC
Power Consumption9 W
Operating Humidity0% to 95% RH (non-condensing)
Max Ambient Temp250°F at element
Max Pressure200 psi (well), 100 psi (direct immersion)
Dimensions (H × W × D)7-1/8″ × 5-1/4″ × 3-7/16″
Weight6.00 lbs
Product typeBurner Control