Description  The Keyence GL-T11R is a dedicated safety relay terminal designed for use with the GL-R Series safety light curtains. It provides reliable safety signal control and monitoring with high electrical durability, fast response times, and multiple input/output options for industrial automation safety systems.     Technical Specifications  Condition New/Never Used Surplus Brand Keyence Category Safety Systems Part Number GL-T11R Subcategory Light Curtain Applicable Model GL-R Series Relay Output 250 VAC 6 A / 30 VDC 6 A (resistive load) Electrical Life-span 100,000 cycles or more at rated load Response Time (ON–OFF) GL-R +10 ms Response Time (OFF–ON) GL-R +32 ms AUX Output Transistor (PNP/NPN), 50 mA max, 2.5 V residual voltage Error Output Available Muting Lamp Output 24 VDC incandescent or LED lamp (10–230 mA) External Inputs EDM, Wait, Reset, Muting, Override Input Voltage Levels ON: 5 V–Power supply voltage; OFF: 0–3 V Power Supply Voltage 24 VDC ±10%, Class 2 Current Consumption 100 mA max Enclosure Rating IP20 (must be installed in IP54+ panel) Operating Temperature Range -10 to +55 °C (14 to 131 °F) Storage Temperature Range -25 to +60 °C (-13 to 140 °F) Operating Humidity 15–85% RH (no condensation) Storage Humidity 15–95% RH Altitude Limit 2000 m or less Vibration Resistance 10–55 Hz, 0.7 mm amplitude, 20 sweeps/axis Shock Resistance 100 m/s² (approx. 10 G), 16 ms pulse Safety Standards EN61496-1, ISO13849-1 (PLe), UL508, EN50178 Material Polycarbonate Weight Approx. 310 g (0.68 lb)     Information About GL-T11R The GL-T11R is part of Keyence’s GL-R Series safety system accessories, engineered for dependable safety relay control in hazardous machinery and equipment. It operates on a 24 VDC power supply and features dual FSD relay outputs rated for up to 250 VAC or 30 VDC loads. The unit includes multiple auxiliary and muting outputs, external input compatibility, and advanced safety certifications including IEC61496-1 and ISO13849-1. Its polycarbonate housing, IP20 rating, and vibration/shock resistance ensure long-term operation when installed in protected control panels. Key Features: Dedicated for GL-R Series: Specifically designed for use with Keyence GL-R safety light curtains. High Relay Capacity: Supports 250 VAC 6 A or 30 VDC 6 A resistance loads for flexible safety control. Durable Electrical Life: Rated for over 100,000 switching cycles under standard load conditions. Fast Response Time: Achieves ON–OFF within +10 ms and OFF–ON within +32 ms for quick safety reaction. Multiple Output Options: Includes transistor-type AUX output, error output, and muting lamp output. Wide Environmental Range: Operates reliably from -10 to +55 °C and up to 85% relative humidity. Certified Safety Standards: Complies with EN61496-1, ISO13849-1 (PLe), UL508, and FCC standards. Robust Construction: Polycarbonate body with IP20 protection for control panel installation. Vibration & Shock Resistant: Withstands 10–55 Hz vibration and 100 m/s² shock testing. Compact and Lightweight: Easy to integrate into existing safety control systems. The GL-T11R delivers the reliability and performance required for advanced machine guarding and safety relay operations in automated environments.

Brand: Keyence · Category: Relays, Contactors & Switches

Key features

Specifications

Manufacturer part numberGL-T11R
ConditionNew/Never Used Surplus
BrandKeyence
CategorySafety Systems
Part NumberGL-T11R
SubcategoryLight Curtain
Applicable ModelGL-R Series
Relay Output250 VAC 6 A / 30 VDC 6 A (resistive load)
Electrical Life-span100,000 cycles or more at rated load
Response Time (ON–OFF)GL-R +10 ms
Response Time (OFF–ON)GL-R +32 ms
AUX OutputTransistor (PNP/NPN), 50 mA max, 2.5 V residual voltage
Error OutputAvailable
Muting Lamp Output24 VDC incandescent or LED lamp (10–230 mA)
External InputsEDM, Wait, Reset, Muting, Override
Input Voltage LevelsON: 5 V–Power supply voltage; OFF: 0–3 V
Power Supply Voltage24 VDC ±10%, Class 2
Current Consumption100 mA max
Enclosure RatingIP20 (must be installed in IP54+ panel)
Operating Temperature Range-10 to +55 °C (14 to 131 °F)
Storage Temperature Range-25 to +60 °C (-13 to 140 °F)
Operating Humidity15–85% RH (no condensation)
Storage Humidity15–95% RH
Altitude Limit2000 m or less
Vibration Resistance10–55 Hz, 0.7 mm amplitude, 20 sweeps/axis
Shock Resistance100 m/s² (approx. 10 G), 16 ms pulse
Safety StandardsEN61496-1, ISO13849-1 (PLe), UL508, EN50178
MaterialPolycarbonate
WeightApprox. 310 g (0.68 lb)
Product typeLight Curtain