SNAC-6 | Gamewell-FCI Supplementary Notification Appliance Circuit Panel, 6A Output

Gamewell-FCI · Industrial Automation & Electrical

SNAC-6 | Gamewell-FCI Supplementary Notification Appliance Circuit Panel, 6A Output

Description  The Gamewell-FCI SNAC-6 is a supplementary notification appliance circuit panel that provides up to 6 amps of power across multiple Class A or Class B circuits. It integrates with existing notification appliance circuits, offering synchronization, temporal pattern outputs, and full supervision for reliable fire alarm signaling.     Technical Specifications  Condition New/Never Used Surplus Brand Gamewell-FCI Category Fire Alarm Systems Part Number SNAC-6 Subcategory NAC Panels Type Supplementary notification appliance circuit panel Output Capacity 6 A total Output Circuits 2 Class A (Style Z), 4 Class B (Style Y), or 1 Class A + 2 Class B Input Source 1 or 2 existing Class A/B NACs Operating Voltage 9–32 VDC Operation Modes Coded or non-coded Temporal Pattern Programmable ANSI S3.41 temporal Class B output from non-coded input Synchronization Built-in sync for strobes from 3 manufacturers Ground Fault Detection Integral supervision with ground fault detection Trouble Reporting Form “C” contacts, delayed AC failure indication Compliance UL Listed fire alarm accessory Applications Expands NAC capacity for FCI and other UL Listed fire alarm systems Dimensions 16.00 × 12.25 × 3.00 in Weight 6.5 lbs   Information About SNAC-6 The SNAC-6 is a UL Listed supplementary notification appliance circuit panel engineered to expand the signaling capabilities of fire alarm systems. It provides up to 6 amps of regulated output that can be distributed across Class A or Class B circuits, depending on installation needs. With the ability to synchronize strobes from three leading manufacturers, it ensures consistent visual signaling across facilities. Additional features include ANSI S3.41 temporal pattern outputs, coded/non-coded operation, ground fault detection, and Form “C” trouble contacts. Designed for compatibility with Gamewell-FCI and other UL Listed control panels, the SNAC-6 enhances both capacity and reliability in life safety applications. Key Features: High current output: Provides 6 amps of total NAC power for supporting multiple notification appliances. Flexible circuit configuration: Supports 2 Class A, 4 Class B, or mixed 1 Class A and 2 Class B circuits to fit system requirements. Input circuit integration: Activates through one or two existing Class A or B notification appliance circuits for seamless expansion. Coded and non-coded operation: Allows flexible control options, including compatibility with coded inputs. Programmable temporal outputs: Provides ANSI S3.41-compliant temporal Class B outputs from non-coded inputs. Strobe synchronization: Features built-in synchronization for appliances from three major manufacturers. Supervised operation: Equipped with ground fault detection to ensure circuit integrity. Trouble monitoring: Includes Form “C” trouble contacts with delayed AC failure indication for enhanced system reporting. UL Listed accessory: Approved for use with Gamewell-FCI and other UL Listed fire alarm systems. Durable enclosure: Measures 16 × 12.25 × 3 inches and weighs 6.5 lbs for dependable installation. The SNAC-6 delivers the reliability and precision required for expanding NAC capacity and synchronization in commercial and institutional fire alarm systems.

Brand: Gamewell-FCI · Category: Industrial Automation & Electrical

Key features

Specifications

Manufacturer part numberSNAC-6
ConditionNew/Never Used Surplus
BrandGamewell-FCI
CategoryFire Alarm Systems
Part NumberSNAC-6
SubcategoryNAC Panels
TypeSupplementary notification appliance circuit panel
Output Capacity6 A total
Output Circuits2 Class A (Style Z), 4 Class B (Style Y), or 1 Class A + 2 Class B
Input Source1 or 2 existing Class A/B NACs
Operating Voltage9–32 VDC
Operation ModesCoded or non-coded
Temporal PatternProgrammable ANSI S3.41 temporal Class B output from non-coded input
SynchronizationBuilt-in sync for strobes from 3 manufacturers
Ground Fault DetectionIntegral supervision with ground fault detection
Trouble ReportingForm “C” contacts, delayed AC failure indication
ComplianceUL Listed fire alarm accessory
ApplicationsExpands NAC capacity for FCI and other UL Listed fire alarm systems
Dimensions16.00 × 12.25 × 3.00 in
Weight6.5 lbs
Product typeNAC Panels

Contact Safety Shops for pricing, delivery and project support in the UAE.