Description  The Beckhoff EL3112 is a 2-channel EtherCAT Terminal for differential analog current measurement in the range of 0–20 mA. With 16-bit resolution, fast conversion time, and advanced filter options, it ensures accurate data acquisition in industrial automation systems.     Technical Specifications  Condition New/Never Used Surplus Brand Beckhoff Category I/O Terminals Part Number EL3112 Subcategory EtherCAT Analog Input Terminals Protocol EtherCAT Number of Inputs 2 (differential) Signal Current 0…20 mA Resolution 16-bit (including sign) Conversion Time ~50 µs (fast mode ~35 µs) Input Filter Limit Frequency 5 kHz Common-Mode Voltage max. 10 V Internal Resistance typ. 85 Ω + diode voltage Measurement Error < ±0.3% (relative to full scale) Distributed Clocks Yes Distributed Clock Precision < 1 µs Surge Voltage Resistance 35 V DC Electrical Isolation 500 V (E-bus/signal voltage) Current Consumption (E-bus) typ. 170 mA Power Supply via E-bus Bit Width in Process Image Inputs: 8 byte Special Features Standard/compact process image, FIR/IIR filters, limit value monitoring Operating Temperature -25…+60 °C Storage Temperature -40…+85 °C Relative Humidity 95%, no condensation Dimensions (W x H x D) 12 x 100 x 68 mm Material Polycarbonate Installation 35 mm DIN rail (EN 60715) with lock Weight approx. 55 g   Information About EL3112 The EL3112 is part of Beckhoff’s EtherCAT I/O terminal family, designed for precise analog current measurement in distributed automation systems. It features two differential inputs capable of measuring currents in the 0–20 mA range, supporting high-resolution data acquisition for process monitoring and control. With 16-bit resolution, distributed clocks with <1 µs precision, and fast conversion times down to 35 µs, the EL3112 offers both speed and accuracy for demanding applications. Its advanced features include configurable FIR/IIR filters, compact or standard process image modes, and limit value monitoring, making it suitable for a wide variety of industrial control environments. Key Features: Dual Analog Inputs: Provides two differential input channels for current signals up to 20 mA. High Resolution: 16-bit signed resolution ensures accurate measurement and fine signal detail. Fast Conversion Time: Supports standard conversion at 50 µs and fast mode at 35 µs for dynamic applications. Advanced Synchronization: Distributed clock support with <1 µs precision enables precise system-wide timing. Flexible Filtering Options: Configurable FIR/IIR filters and 5 kHz input bandwidth improve signal quality. Integrated Safety Features: Limit value monitoring and 35 V surge voltage resistance protect connected systems. Rugged Industrial Design: Electrically isolated up to 500 V between E-bus and signal voltage for secure operation. Compact Form Factor: Slim 12 mm housing with DIN rail installation allows easy integration into control cabinets. Wide Environmental Tolerance: Operates between -25 °C and +60 °C and supports up to 95% humidity without condensation. Low Power Consumption: Draws only 170 mA from the E-bus for efficient system operation. The EL3112 delivers the reliability and precision required for high-speed, high-accuracy current measurement in EtherCAT-based industrial automation systems.

Brand: Beckhoff · Category: Cables & Connectivity

Key features

Specifications

Manufacturer part numberEL3112
ConditionNew/Never Used Surplus
BrandBeckhoff
CategoryI/O Terminals
Part NumberEL3112
SubcategoryEtherCAT Analog Input Terminals
ProtocolEtherCAT
Number of Inputs2 (differential)
Signal Current0…20 mA
Resolution16-bit (including sign)
Conversion Time~50 µs (fast mode ~35 µs)
Input Filter Limit Frequency5 kHz
Common-Mode Voltagemax. 10 V
Internal Resistancetyp. 85 Ω + diode voltage
Measurement Error< ±0.3% (relative to full scale)
Distributed ClocksYes
Distributed Clock Precision< 1 µs
Surge Voltage Resistance35 V DC
Electrical Isolation500 V (E-bus/signal voltage)
Current Consumption (E-bus)typ. 170 mA
Power Supplyvia E-bus
Bit Width in Process ImageInputs: 8 byte
Special FeaturesStandard/compact process image, FIR/IIR filters, limit value monitoring
Operating Temperature-25…+60 °C
Storage Temperature-40…+85 °C
Relative Humidity95%, no condensation
Dimensions (W x H x D)12 x 100 x 68 mm
MaterialPolycarbonate
Installation35 mm DIN rail (EN 60715) with lock
Weightapprox. 55 g