CHB230GF | Eaton CH 30A 2-Pole 120/240V GFCI Molded Case Circuit Breaker

Eaton · Circuit Breakers & Protection

CHB230GF | Eaton CH 30A 2-Pole 120/240V GFCI Molded Case Circuit Breaker

Description  The Eaton CHB230GF is a two-pole ground fault circuit breaker designed to provide personnel protection and overcurrent protection in residential electrical systems. Rated at 30A and 120/240VAC, the Eaton CHB230GF combines thermal magnetic protection with ground fault detection for use in CH loadcenters.     Technical Specifications  Condition New/Never Used Surplus Brand Eaton Category Circuit Breaker Part Number CHB230GF Subcategory Molded Case Series CHB Breaker Type Ground Fault Circuit Breaker (GFCI) Current Rating 30 Amps Voltage Rating 120/240 VAC Poles 2 Phase Single Phase Interrupting Rating 10 kAIC at 120/240 VAC Trip Unit Type Thermal Magnetic Trip Functions Long-Time and Instantaneous Ground Fault Sensitivity 5 mA Connection Type Bolt-On Wire Size Range #8 to #4 AWG Cu/Al For Use With Eaton CH Loadcenters Certifications UL 489 Temperature Rating 40 °C Weight 0.9 lb     Information About CHB230GF The CHB230GF is part of Eaton’s CH series, engineered specifically for compatibility with CH loadcenters in residential power distribution. It incorporates a thermal magnetic trip unit with long-time and instantaneous response to protect against overloads and short circuits. The breaker includes integrated ground fault protection with a 5 mA trip sensitivity to reduce the risk of electrical shock. Designed with bolt-on line-side terminals and lug-style load connections, it supports secure installation using copper or aluminum conductors. Key Features: Ground Fault Protection: Provides 5 mA ground fault trip sensitivity for personnel safety. CH Series Compatibility: Designed exclusively for Eaton CH loadcenters. Thermal Magnetic Trip Unit: Delivers long-time and instantaneous protection against faults. 30 Amp Current Rating: Suitable for residential branch and feeder circuits. Two-Pole Configuration: Supports 120/240V single-phase electrical systems. 10 kA Interrupting Rating: Safely interrupts fault currents at residential service levels. Bolt-On Connection: Ensures secure mechanical and electrical installation. The CHB230GF delivers the reliability and precision required for residential ground fault and overcurrent circuit protection.

Brand: Eaton · Category: Circuit Breakers & Protection

Key features

Specifications

Manufacturer part numberCHB230GF
ConditionNew/Never Used Surplus
BrandEaton
CategoryCircuit Breaker
Part NumberCHB230GF
SubcategoryMolded Case
SeriesCHB
Breaker TypeGround Fault Circuit Breaker (GFCI)
Current Rating30 Amps
Voltage Rating120/240 VAC
Poles2
PhaseSingle Phase
Interrupting Rating10 kAIC at 120/240 VAC
Trip Unit TypeThermal Magnetic
Trip FunctionsLong-Time and Instantaneous
Ground Fault Sensitivity5 mA
Connection TypeBolt-On
Wire Size Range#8 to #4 AWG Cu/Al
For Use WithEaton CH Loadcenters
CertificationsUL 489
Temperature Rating40 °C
Weight0.9 lb
Product typeMolded Case