APS2-6R | Notifier 24VDC 150W Auxiliary Power Supply (6A Alarm / 4A Continuous)

Notifier · Fire & Life Safety

APS2-6R | Notifier 24VDC 150W Auxiliary Power Supply (6A Alarm / 4A Continuous)

Description  The Notifier APS2-6R is a 150-watt auxiliary power supply designed to provide 24 VDC of filtered DC power for peripheral devices on ONYX Series fire alarm control panels. It delivers three output circuits rated for 6.0 amps in alarm and 4.0 amps continuous operation.     Technical Specifications  Condition New/Never Used Surplus Brand Notifier Category Flame Safety Products Part Number APS2-6R Subcategory Power Supply Power Rating 150 W Output Voltage 24 VDC filtered Output Current 6.0 A alarm, 4.0 A continuous Number of Circuits 3 output circuits AC Input (APS2-6R) 120 VAC, 50/60 Hz, 2.9 A AC Input (APS2-6RE) 220–240 VAC, 50/60 Hz, 1.5 A DC Secondary Input 24 VDC nominal Relay Contacts AC Fail supervision via SLC Fuse Protection 32 VDC, 10.0 A automotive minifuse Indicators Diagnostic trouble LED Supervision Battery voltage, low battery disconnect, trouble bus Terminal Capacity Up to 12 AWG (3.1 mm²) Dimensions 8.625" x 6.625" x 2.375" (21.91 x 16.83 x 6.03 cm) Weight 2 lbs (0.91 kg) Certifications UL Listed (S635), FM Approved, CSFM (7315-0028:248), FDNY COA #6028 Mounting CAB-3 and CAB-4 Series cabinets     Information About APS2-6R The APS2-6R is a compact, UL 864 Ninth Edition compliant auxiliary power supply built for fire alarm and life safety systems. It supports both 120 VAC and 220/240 VAC inputs and incorporates overload protection, brown-out circuitry, and diagnostic trouble LEDs. Designed to integrate seamlessly with Notifier’s ONYX Series, it shares the battery and charger circuits with the control panel, ensuring system reliability. The APS2-6R mounts in standard CAB-3 or CAB-4 Series enclosures and can also be used with legacy panels. Key Features: High Output Capacity: 150-watt design with three 24 VDC outputs at 6.0 A alarm / 4.0 A continuous. AC Input Flexibility: Operates on 120 VAC or 220/240 VAC at 50/60 Hz. Built-in Protections: Overload and brown-out circuitry for system safety. Trouble Monitoring: Diagnostic LED and supervised trouble bus integration. Battery Supervision: Includes low battery disconnect and monitoring. Flexible Installation: Mounts in CAB-3 and CAB-4 series cabinets. Heavy-Duty Terminals: Accepts up to 12 AWG wiring for secure connections. Certified Compliance: UL, FM, CSFM, and FDNY approved for fire system use. The APS2-6R delivers the reliable auxiliary power capacity required for scalable fire alarm control systems.

Brand: Notifier · Category: Fire & Life Safety

Key features

Specifications

Manufacturer part numberAPS2-6R
ConditionNew/Never Used Surplus
BrandNotifier
CategoryFlame Safety Products
Part NumberAPS2-6R
SubcategoryPower Supply
Power Rating150 W
Output Voltage24 VDC filtered
Output Current6.0 A alarm, 4.0 A continuous
Number of Circuits3 output circuits
AC Input (APS2-6R)120 VAC, 50/60 Hz, 2.9 A
AC Input (APS2-6RE)220–240 VAC, 50/60 Hz, 1.5 A
DC Secondary Input24 VDC nominal
Relay ContactsAC Fail supervision via SLC
Fuse Protection32 VDC, 10.0 A automotive minifuse
IndicatorsDiagnostic trouble LED
SupervisionBattery voltage, low battery disconnect, trouble bus
Terminal CapacityUp to 12 AWG (3.1 mm²)
Dimensions8.625" x 6.625" x 2.375" (21.91 x 16.83 x 6.03 cm)
Weight2 lbs (0.91 kg)
CertificationsUL Listed (S635), FM Approved, CSFM (7315-0028:248), FDNY COA #6028
MountingCAB-3 and CAB-4 Series cabinets
Product typePower Supply