AFC-50 | Potter Addressable Fire Alarm Control Panel, 50 Points, IP Communicator, 5A Power
Potter · Fire & Life Safety
Description The Potter AFC-50 is an intelligent analog addressable fire alarm control panel supporting up to 50 devices. Designed for small to medium-sized facilities, it provides reliable detection, communication, and control through flexible SLC configurations. With built-in networking, power expansion, and strobe synchronization, the AFC-50 ensures scalable fire protection with comprehensive system integration. Technical Specifications Condition New/Never Used Surplus Brand Potter Category Fire Alarm Equipment Part Number AFC-50 Subcategory Control Panels Type Analog Addressable Fire Alarm Control Panel Device Capacity 50 addressable points (expandable with multi-point SLC modules) Zones 99 software zones Display LCD user interface with menu navigation Relays Dedicated Alarm, Supervisory, and Trouble relays Power Supply 5 Amps standard, expandable up to 310 Amps with PSN-1000 NAC Circuits Two Class A/B NACs, 3 Amps each, expandable up to 188 I/O Circuits Two Class A/B I/O circuits, 1 Amp each Strobe Sync Gentex, AMSECO, System Sensor, Cooper Wheelock with Quadrasync Communication Built-in IP communicator; optional two-line DACT Programming Ethernet port for programming and network connectivity Event History 4,000-event history buffer Battery Charger 8–55 Ah, 27.3 VDC output Operating Range 32° to 120°F (0° to 49°C), up to 93% non-condensing humidity Enclosure 16-gauge cold rolled steel with locking door and Lexan window Approvals NFPA, UL 864, IBC, CS, RS, PPU, AUX, DAC, March, NC, Rev Pol, OT Dimensions 16” W × 17” H × 3” D Weight 16 lbs Information About AFC-50 The AFC-50 is part of Potter’s line of analog addressable fire alarm systems, offering modular expansion and advanced communication features. It operates with the exclusive Potter protocol, supporting a full range of sensors, heat detectors, and modules on a single SLC. Equipped with a 5-amp power supply, multiple NACs, and I/O circuits, the AFC-50 is engineered to meet NFPA and UL standards for dependable life safety. Its built-in IP communicator, Ethernet programming port, and optional DACT provide flexible connectivity options, making it suitable for diverse building applications. Key Features: Device Capacity: Supports up to 50 addressable points with expansion via SLC modules. Power Supply: 5-amp capacity with two regulated 3-amp NACs and two 1-amp I/O circuits. Strobe Synchronization: System-wide Quadrasync technology for Gentex, AMSECO, System Sensor, and Cooper Wheelock devices. Expandable Power: Compatible with up to 31 PSN-1000 intelligent power supplies, adding up to 310 amps. Built-in Communication: Integrated IP communicator with optional DACT for zone or point reporting. Programming and Control: Ethernet port for configuration, email status reporting, and event notifications. History Storage: 4,000-event history buffer for long-term system tracking. Compliance: Meets NFPA 72, ANSI/UL 864, and IBC code requirements. The AFC-50 delivers the reliability and precision required for intelligent addressable fire detection and facility protection.
Brand: Potter · Category: Fire & Life Safety
Key features
- Device Capacity: Supports up to 50 addressable points with expansion via SLC modules.
- Power Supply: 5-amp capacity with two regulated 3-amp NACs and two 1-amp I/O circuits.
- Strobe Synchronization: System-wide Quadrasync technology for Gentex, AMSECO, System Sensor, and Cooper Wheelock devices.
- Expandable Power: Compatible with up to 31 PSN-1000 intelligent power supplies, adding up to 310 amps.
- Built-in Communication: Integrated IP communicator with optional DACT for zone or point reporting.
- Programming and Control: Ethernet port for configuration, email status reporting, and event notifications.
- History Storage: 4,000-event history buffer for long-term system tracking.
- Compliance: Meets NFPA 72, ANSI/UL 864, and IBC code requirements.
Specifications
| Manufacturer part number | AFC-50 |
|---|---|
| Condition | New/Never Used Surplus |
| Brand | Potter |
| Category | Fire Alarm Equipment |
| Part Number | AFC-50 |
| Subcategory | Control Panels |
| Type | Analog Addressable Fire Alarm Control Panel |
| Device Capacity | 50 addressable points (expandable with multi-point SLC modules) |
| Zones | 99 software zones |
| Display | LCD user interface with menu navigation |
| Relays | Dedicated Alarm, Supervisory, and Trouble relays |
| Power Supply | 5 Amps standard, expandable up to 310 Amps with PSN-1000 |
| NAC Circuits | Two Class A/B NACs, 3 Amps each, expandable up to 188 |
| I/O Circuits | Two Class A/B I/O circuits, 1 Amp each |
| Strobe Sync | Gentex, AMSECO, System Sensor, Cooper Wheelock with Quadrasync |
| Communication | Built-in IP communicator; optional two-line DACT |
| Programming | Ethernet port for programming and network connectivity |
| Event History | 4,000-event history buffer |
| Battery Charger | 8–55 Ah, 27.3 VDC output |
| Operating Range | 32° to 120°F (0° to 49°C), up to 93% non-condensing humidity |
| Enclosure | 16-gauge cold rolled steel with locking door and Lexan window |
| Approvals | NFPA, UL 864, IBC, CS, RS, PPU, AUX, DAC, March, NC, Rev Pol, OT |
| Dimensions | 16” W × 17” H × 3” D |
| Weight | 16 lbs |
| Product type | Control Panels |