Description  The Potter AFC-1000 is an expandable analog addressable fire alarm control panel supporting up to 1,270 points. It features a 10-amp power supply, six regulated NACs, four programmable I/O circuits, built-in IP communication, and extensive event logging for large-scale fire protection systems.     Technical Specifications  Condition New/Never Used Surplus Brand Potter Category Fire Alarm Systems Part Number AFC-1000 Subcategory Addressable Fire Alarm Control Panel System Capacity 1,270 addresses (expandable with multi-point SLC modules) Zones 1,500 software zones Event History 4,000 events Power Supply 10 A, expandable to 315 A Notification Appliance Circuits (NACs) 6 outputs, 3 A each, expandable to 192 Input/Output Circuits 4 outputs, 1 A each Synchronization System Sensor, Gentex, Cooper/Wheelock, AMSECO; Quadrasync supported Smoke Sensitivity Test NFPA 72 Compliant, built-in Communication Built-in IP communicator, optional two-line DACT (UD-2000) Network Interface Ethernet port for programming and monitoring Email Reporting System status, reports, and event notifications Dedicated Relays Alarm, Supervisory, and Trouble AC Input 120 VAC, 5.0 A or 240 VAC, 3.0 A, 50/60 Hz Battery Charger 8–55 Ah, 27.3 VDC output Standby Current 130 mA Alarm Current 220 mA P-Link Current 1 A max Enclosure 16-gauge cold rolled steel with locked door and Lexan viewing window Dimensions 18 15/16 in W x 27 5/16 in H x 4 7/16 in D Temperature Range 32° to 120°F (0° to 49°C), 93% max humidity (non-condensing) Standards NFPA 13, 15, 16, 17, 17A, 70, 72, 750; ANSI/UL 864; IBC Weight 16 lbs     Information About AFC-1000 The AFC-1000 is a Potter analog addressable fire alarm control panel built for high-capacity installations, with support for up to 1,270 devices on a single system. It offers six NAC outputs and four programmable I/O circuits, all regulated and configurable for steady signal, synchronization, constant power, releasing, or door holder power. The system incorporates Quadrasync technology, allowing multiple strobe brands to flash in sync across different outputs. With built-in IP communication, Ethernet connectivity, and optional DACT, the AFC-1000 delivers extensive networking and reporting functions, while its 4,000-event buffer and NFPA 72 smoke sensitivity test support compliance and detailed monitoring. Key Features: Large System Capacity: Supports 1,270 addressable devices with expansion through multi-point SLC modules. High Output Power: Includes a 10 A regulated power supply expandable up to 315 A for large installations. Multiple NACs and I/Os: Provides six NACs rated at 3 A each and four I/O circuits rated at 1 A each, fully programmable. Quadrasync Strobe Control: Synchronizes strobes from Gentex, System Sensor, AMSECO, and Wheelock simultaneously across outputs. Event Tracking: 4,000-event history buffer ensures comprehensive system monitoring and troubleshooting. Built-in Communication: Features integrated IP communicator and Ethernet connectivity with optional two-line DACT. Flexible Programming: 1,500 software zones for detailed system configuration and management. Compliance Ready: Meets NFPA 72 standards with built-in smoke sensitivity testing. Rugged Construction: Housed in a steel enclosure with locked Lexan window for durability and security. Environmental Resilience: Operates from 32° to 120°F with up to 93% humidity non-condensing. The AFC-1000 delivers the reliability and precision required for managing large and complex fire alarm systems in commercial, institutional, and industrial facilities.

Brand: Potter · Category: Fire & Life Safety

Key features

Specifications

Manufacturer part numberAFC-1000
ConditionNew/Never Used Surplus
BrandPotter
CategoryFire Alarm Systems
Part NumberAFC-1000
SubcategoryAddressable Fire Alarm Control Panel
System Capacity1,270 addresses (expandable with multi-point SLC modules)
Zones1,500 software zones
Event History4,000 events
Power Supply10 A, expandable to 315 A
Notification Appliance Circuits (NACs)6 outputs, 3 A each, expandable to 192
Input/Output Circuits4 outputs, 1 A each
SynchronizationSystem Sensor, Gentex, Cooper/Wheelock, AMSECO; Quadrasync supported
Smoke Sensitivity TestNFPA 72 Compliant, built-in
CommunicationBuilt-in IP communicator, optional two-line DACT (UD-2000)
Network InterfaceEthernet port for programming and monitoring
Email ReportingSystem status, reports, and event notifications
Dedicated RelaysAlarm, Supervisory, and Trouble
AC Input120 VAC, 5.0 A or 240 VAC, 3.0 A, 50/60 Hz
Battery Charger8–55 Ah, 27.3 VDC output
Standby Current130 mA
Alarm Current220 mA
P-Link Current1 A max
Enclosure16-gauge cold rolled steel with locked door and Lexan viewing window
Dimensions18 15/16 in W x 27 5/16 in H x 4 7/16 in D
Temperature Range32° to 120°F (0° to 49°C), 93% max humidity (non-condensing)
StandardsNFPA 13, 15, 16, 17, 17A, 70, 72, 750; ANSI/UL 864; IBC
Weight16 lbs
Product typeAddressable Fire Alarm Control Panel