57120-M3 | Leviton Type 2 3-Phase Surge Panel with Replaceable Surge Modules

Leviton · Circuit Breakers & Protection

57120-M3 | Leviton Type 2 3-Phase Surge Panel with Replaceable Surge Modules

Description  The Leviton 57120-M3 is a Type 2 3-phase surge protective panel for 120/208 V Wye systems, featuring replaceable surge modules, 150 kA per-phase capacity, and advanced diagnostics for reliable facility-wide surge protection.     Technical Specifications  Condition New/Never Used Surplus Brand Leviton Category Panel Accessories Part Number 57120-M3 Subcategory Surge Arrestor/Suppressor Frequency 50/60 Hz Voltage Configuration 120/208 V, 3-Phase Wye Recommended Circuit Breaker Rating 30 A, 120 V Surge Technology 40 mm MOV Design Protection Mode 4-Mode (L-N, L-G, N-G, L-L) Maximum Surge Current, Per Mode (Per Phase) 150 kA (300 kA total) MCOV L-N: 150 V, L-G: 300 V, N-G: 150 V, L-L: 300 V Nominal Discharge Current Rating 20 kA Short Circuit Current Rating 100 kA VPR L-N: 1000 V, L-G: 1500 V, N-G: 800 V, L-L: 1500 V Transient Energy per Phase 2000 J Noise Rejection –20 to –40 dB at 5 kHz–10 MHz Enclosure Type 12 / NEMA 12 hinged Flammability Rated V-2 per UL 94 Operating Temperature –20 °C to 40 °C Storage Temperature –20 °C to 85 °C (–4 °F to 185 °F) Relative Humidity 5 % to 95 %, non-condensing Connection Type Parallel-hardwired, feed-through dual-wire terminal block (accepts up to #3 AWG) Mounting Panel surface / flush Replaceable Modules Yes Surge Counter No Diagnostics Real-time protection status LEDs & audible alarm Remote Monitoring Dry contact leads, N.O./N.C. Form C, rated 7 A @ 240 VAC or 30 VDC Standards UL 1449 (3rd Ed.), CSA, ANSI/IEEE C-62.41 & C-62.45 (Categories A, B, C) Type Modular dual-stage fused Design Use Distribution panel Model 57120-M3 Multiple Phase Modular Panel System Weight 15.00 lbs     Information About 57120-M3 The Leviton 57120-M3 is a modular Type 2 surge protective device designed for 120/208 V 3-phase Wye distribution panels. Built with replaceable and redundant surge modules, it provides continuous high-capacity protection of up to 150 kA per phase, safeguarding electrical systems from transient overvoltages. Its NEMA 12 steel enclosure, dual-stage fused design, and advanced diagnostics make it ideal for demanding commercial and industrial environments. Real-time status LEDs, an audible alarm, and remote monitoring capabilities ensure timely alerts and maintenance readiness. Key Features: High Surge Capacity: 150 kA per phase (300 kA total) with 4-mode protection (L-N, L-G, N-G, L-L). Replaceable Surge Modules: Modular design with 3× 7120 and 1× 8120-GN units for easy maintenance. Advanced Diagnostics: Real-time status LEDs, audible alarm, and Form C dry contacts for remote monitoring. Robust Construction: NEMA 12 powder-coated steel enclosure with UL 94 V-2 flammability rating. Noise Filtering: –20 dB to –40 dB attenuation at 5 kHz–10 MHz for improved power quality. Environmental Resilience: Operates from –20 °C to +40 °C and in 5–95 % non-condensing humidity. Standards Compliance: UL 1449 3rd Edition, CSA, and ANSI/IEEE C-62.41 & C-62.45 (Categories A, B, C). Flexible Wiring: Parallel-hardwired terminal blocks accept up to #3 AWG wire for easy installation. The 57120-M3 delivers reliable, high-performance surge protection for critical electrical infrastructure, ensuring operational continuity and equipment longevity.

Brand: Leviton · Category: Circuit Breakers & Protection

Key features

Specifications

Manufacturer part number57120-M3
ConditionNew/Never Used Surplus
BrandLeviton
CategoryPanel Accessories
Part Number57120-M3
SubcategorySurge Arrestor/Suppressor
Frequency50/60 Hz
Voltage Configuration120/208 V, 3-Phase Wye
Recommended Circuit Breaker Rating30 A, 120 V
Surge Technology40 mm MOV Design
Protection Mode4-Mode (L-N, L-G, N-G, L-L)
Maximum Surge Current, Per Mode (Per Phase)150 kA (300 kA total)
MCOVL-N: 150 V, L-G: 300 V, N-G: 150 V, L-L: 300 V
Nominal Discharge Current Rating20 kA
Short Circuit Current Rating100 kA
VPRL-N: 1000 V, L-G: 1500 V, N-G: 800 V, L-L: 1500 V
Transient Energy per Phase2000 J
Noise Rejection–20 to –40 dB at 5 kHz–10 MHz
EnclosureType 12 / NEMA 12 hinged
FlammabilityRated V-2 per UL 94
Operating Temperature–20 °C to 40 °C
Storage Temperature–20 °C to 85 °C (–4 °F to 185 °F)
Relative Humidity5 % to 95 %, non-condensing
Connection TypeParallel-hardwired, feed-through dual-wire terminal block (accepts up to #3 AWG)
MountingPanel surface / flush
Replaceable ModulesYes
Surge CounterNo
DiagnosticsReal-time protection status LEDs & audible alarm
Remote MonitoringDry contact leads, N.O./N.C. Form C, rated 7 A @ 240 VAC or 30 VDC
StandardsUL 1449 (3rd Ed.), CSA, ANSI/IEEE C-62.41 & C-62.45 (Categories A, B, C)

Contact Safety Shops for pricing, delivery and project support in the UAE.