3VA4112-6ED34-0AA0 | Siemens 3VA4 125A 3-Pole 480V Thermal-Magnetic Circuit Breaker
Siemens · Circuit Breakers & Protection
Description The Siemens® 3VA4112-6ED34-0AA0 is a 3-pole, 125A thermal-magnetic molded case circuit breaker (MCCB) from the 3VA4 SENTRON series, designed for dependable line protection in industrial and commercial electrical systems. Operating at up to 600Y/347V AC with a breaking capacity of 65 kA at 480V, it ensures precise overload and short-circuit protection through its TM210 trip unit. Compact, durable, and UL489 compliant, this breaker is ideal for applications requiring high interrupting capacity and continuous performance reliability. Technical Specifications Condition New/Never Used Surplus Brand Siemens Category Circuit Protection Devices Part Number 3VA4112-6ED34-0AA0 Subcategory Molded Case Circuit Breaker Series SENTRON 3VA4 Frame Type 3VA41 Poles 3 Rated Current (In) 125 A Rated Voltage (AC) 600Y/347V, 480V, 690V (max) Trip Unit Type TM210 (Thermal-Magnetic, LI) Breaking Capacity 65 kA @ 480V, 25 kA @ 600Y/347V Protection Function Long-time overload (Ir), instantaneous short-circuit (Ii) Overload Protection Setting (Ir) 125 A (fixed) Short-Circuit Protection Setting (Ii) 10 × In (fixed) Terminal Connection Type Load side lug Design / Type System and line protection breaker Mounting Type Fixed / Panelboard Protection Rating IP20 Endurance (Mechanical) 15,000 operations Endurance (Electrical) 8,000 @ 480V, 4,000 @ 600V Power Loss (Max) 29.1 W total (9.7 W per pole) Compliance / Approvals UL489, HACR Type Ground Fault Monitoring Not included Country of Origin Germany / Mexico (depending on lot) Net Weight 0.743 kg (1.64 lbs) Information About 3VA4112-6ED34-0AA0 The 3VA4112-6ED34-0AA0 is part of the Siemens 3VA4 UL-rated molded case circuit breaker family, engineered for consistent protection of distribution circuits and connected equipment. It features a 3VA41 frame, a Class H high-breaking capacity, and a TM210 LI trip unit offering fixed long-time and instantaneous protection characteristics. With a rated operational voltage of 690V AC and mechanical endurance up to 15,000 operations, this circuit breaker ensures long-term performance even in demanding conditions. The load-side lug terminal design and compact form factor enable straightforward installation in control panels or distribution boards. Its robust construction and compliance with UL489 and HACR standards make it suitable for HVAC, motor protection, and general industrial power distribution applications. Key Features: Thermal-Magnetic Trip Unit (TM210): Provides long-time (Ir) and instantaneous (Ii) overcurrent protection. High Interrupting Capacity: 65kA @ 480V and 25kA @ 600Y/347V for reliable fault protection. Versatile Application Use: UL489 HACR type suitable for heating, air conditioning, and refrigeration systems. Compact 3VA41 Frame: Optimized for high performance with minimal panel space requirements. Wide Voltage Range: Rated for up to 690V AC operation with a continuous current of 125A. Durable Performance: 15,000 mechanical and up to 8,000 electrical operating cycles. Fixed Line Protection Settings: Simplifies commissioning and ensures consistent system coordination. UL Listed and SENTRON Quality: Meets international standards for industrial circuit protection. The 3VA4112-6ED34-0AA0 delivers the precision, durability, and safety demanded in critical power distribution and protection systems.
Brand: Siemens · Category: Circuit Breakers & Protection
Key features
- Thermal-Magnetic Trip Unit (TM210): Provides long-time (Ir) and instantaneous (Ii) overcurrent protection.
- High Interrupting Capacity: 65kA @ 480V and 25kA @ 600Y/347V for reliable fault protection.
- Versatile Application Use: UL489 HACR type suitable for heating, air conditioning, and refrigeration systems.
- Compact 3VA41 Frame: Optimized for high performance with minimal panel space requirements.
- Wide Voltage Range: Rated for up to 690V AC operation with a continuous current of 125A.
- Durable Performance: 15,000 mechanical and up to 8,000 electrical operating cycles.
- Fixed Line Protection Settings: Simplifies commissioning and ensures consistent system coordination.
- UL Listed and SENTRON Quality: Meets international standards for industrial circuit protection.
Specifications
| Manufacturer part number | 3VA4112-6ED34-0AA0 |
|---|---|
| Condition | New/Never Used Surplus |
| Brand | Siemens |
| Category | Circuit Protection Devices |
| Part Number | 3VA4112-6ED34-0AA0 |
| Subcategory | Molded Case Circuit Breaker |
| Series | SENTRON 3VA4 |
| Frame Type | 3VA41 |
| Poles | 3 |
| Rated Current (In) | 125 A |
| Rated Voltage (AC) | 600Y/347V, 480V, 690V (max) |
| Trip Unit Type | TM210 (Thermal-Magnetic, LI) |
| Breaking Capacity | 65 kA @ 480V, 25 kA @ 600Y/347V |
| Protection Function | Long-time overload (Ir), instantaneous short-circuit (Ii) |
| Overload Protection Setting (Ir) | 125 A (fixed) |
| Short-Circuit Protection Setting (Ii) | 10 × In (fixed) |
| Terminal Connection Type | Load side lug |
| Design / Type | System and line protection breaker |
| Mounting Type | Fixed / Panelboard |
| Protection Rating | IP20 |
| Endurance (Mechanical) | 15,000 operations |
| Endurance (Electrical) | 8,000 @ 480V, 4,000 @ 600V |
| Power Loss (Max) | 29.1 W total (9.7 W per pole) |
| Compliance / Approvals | UL489, HACR Type |
| Ground Fault Monitoring | Not included |
| Country of Origin | Germany / Mexico (depending on lot) |
| Net Weight | 0.743 kg (1.64 lbs) |
| Product type | Molded Case Circuit Breaker |
Contact Safety Shops for pricing, delivery and project support in the UAE.